How To Put Your Heater In Bo Mode

Hayward Pool Heater LO Code? Watch This!!

1. Press the Mode button to place the heater in Standby Mode

2. Hold the Down Arrow and Mode buttons simultaneously for 3 seconds for Bypass operation. bo will be displayed on the screen.

3. Heater must then be in the Spa or Pool Mode for operation. The heater will fire when instructed by the external control.

What Does A High Limit Switch Do On A Pool Heater

The high limit switch on a Hayward pool heater is a safety device that is wired in series with the gas valve and the thermostat. If the water temperature going into the pool heater exceeds the maximum set, the gas valve will close, shutting off gas to the burners.

Unusual high-limit operations are a result of problems with the flow of water. Reduced water flow may be caused by

1. Excessive water flow through the external bypass

2. Dirty filters

3. Limescale accumulation in the heat exchanger.

Hayward Heater Lo Code

The Hayward pool heater LO error code is a result of several issues. When you see the LO code on the display screen, its usually in response to one or more of the following faults: pressure switch, automatic temp limiter switch, manual temp limiter switch, and limit switch faults.

Pressure Switch Fault

There are multiple ways to diagnose the pressure switch fault. Start by verifying that the pump is running. If its not, please turn it on. If this doesnt work, proceed to check switch wiring and connections. In particular, look for kink or rodent damages. Youll also want to check terminals for breakage or corrosion.

You can also diagnose the pressure switch fault by measuring switch continuity. Start by removing the wires, then measure the OHMS with the pool pump on. If its closed, the switch is okay. If its open, reconnect the wires and proceed.

Another way to diagnose the pressure switch fault is by checking the water flow. First, ensure the filter and pool pump baskets are clean and no blockage in the impeller. If you have a dirty filter and pool pump baskets, youll need to clean them. Also, unblock the impeller if theres a blockage.

Adjusting the pressure switch can also work when diagnosing the pressure switch fault. So, turn the adjustment screw 1 on clockwise to see if the LO error code disappears. Lastly, the fault could be a result of a defective pressure switch. In this case, replacing it is the best solution.

Automatic or Manual Temp Limiter Switch Fault

Also Check: How To Build An Inexpensive Pool

Control Modules Faulty Wiring Or Improper Connection

The defective connection or improper wiring of the Hayward heater control module is another reason for which your heater displays the CE code. The heaters control module automates and controls the ventilation and heating operation. The factors that cause this trouble are:

  • Heaters power source issue
  • Control modules damaged wiring
  • Faulty wiring of display interface
  • Control module and display interface plugs insecure or inappropriate connection
  • Display interface assembly or control modules malfunction

What Is The Proper Way To Backwash My Pool Filter

Hayward Pool Heater Lo Error Code

What is the proper way to backwash a pool filter. Pump should be turned off, backwash hose should be rolled out, and waste line should be checked for any blocked valves. Backwash a multiport valve by turning the handle backwards, or sliding a push pull valve. Pump should be turned on. Backwash until the water runs clean, which should take around 2-3 minutes. Shut off the pump, reconnect the valve to the filter, and turn the filter back on.

Recommended Reading: How Much Do Fiberglass Pool Inserts Cost

Why Wont My Pool Heater Fire Up

If your heater doesnt power up, this could be mainly due to a defective transformer. Youll need to test voltage across the transformer to troubleshoot this problem. Start by disconnecting the plug from the P4 connector from the Fuse Board. Then measure for 24 VAC across the pins of the transformer. If 24 VAC is not present, replace the transformer.

Vent Pressure Switch Fault

Vent pressure switch fault causes and main fixes

FAULTY VENT PRESSURE POSSIBLE CAUSE FIXES
ENSURE FLUE IS NOT BLOCKED OR RESTRICTED
VENT PRESSURE SWITCH IS DEFECTIVE REPLACE A DEFECTIVE PRESSURE SWITCH

How to diagnose a faulty vent pressure switch.

A faulty vent pressure switch will normally trigger the LO code on your Hayward heater. However, there are a few steps you can take to diagnose and eventually fix a faulty vent pressure switch.

Below are the steps to take to diagnose a faulty pressure switch.

I. Check for faulty wiring or connection

II. Check whether the vent pressure switch contacts are working and can conduct voltage

III. Verify that the flue is not blocked or restricted.

IV. Check whether the vent pressure switch is defective or not.

Vent Pressure Switch FIXES

For each of the diagnostic steps above, the following are possible fixes to each of them.

I. A faulty wiring in the vent pressure switch can cause the LO code. To solve the problem, inspect the wiring on your vent pressure switch and if possible, verify that the wire harness terminals are securely fastened to spade terminals on the vent pressure switch.

Otherwise, if things are ok at this stage, move on to the next step.

II. Verify the status of vent pressure switch contacts. To do this, remove the wire leads from the vent pressure switch and jumper leads. Then turn on the heater and measure for continuity across the vent pressure switch.

Read Also: 4 Person Hot Tub Costco

Incorrect Position Of Bypass Valves

Mainly a bypass valve is used in a pool heater to control the water circulation. It controls the direction of water flow as well. Sometimes, incorrect installation of these valves leads to the water flow restrictions issue.

Because of improper water flowing, the water temperature gets too high, and the heater unit becomes overheated. So, to ensure a fluent heater operation and to get rid of any type of error code, it is needed to the accurate adjustment of the valves.

Environmental And Efficiency Aspects

Hayward Heater AO Error
Learn how and when to remove this template message)

The efficiency of any system depends on the definition of the boundaries of the system. For an electrical energy customer the efficiency of electric space heating is 100% because all purchased energy is converted to heat. However, if a power plant supplying electricity is included, the overall efficiency drops drastically. For example, a fossil-fuel power station only delivers 3-5 units of electrical energy for every 10 units of fuel energy released. Even though the electric heater is 100% efficient, the amount of fuel needed to produce the heat is more than if the fuel were burned in a furnace or boiler at the building being heated. If the same fuel could be used for space heating by a consumer, it would be more efficient overall to burn the fuel at the end user’s building. On the other hand, replacing electric heating with fossil fuel burning heaters, isn’t necessary good as it removes the ability to have renewable electric heating, this can be achieved by sourcing the electricity from a renewable source.

Variations between countries generating electrical power affect concerns about efficiency and the environment. In 2015 France generated only 6% of its electricity from fossil fuels, while Australia sourced over 86% of its electricity from fossil fuels. The cleanliness and efficiency of electricity are dependent on the source.

Learn how and when to remove this template message)

Also Check: What Causes High Ph In Pool

How To Fix Hayward Pool Heater Code Ce

CE stands for Communication Error. CE means the display board and ignition control boards communications error. In simple words, the Hayward pool heater service code ce indicates the control modules communication error. The factors causing the CE code in heater and their resolving ways are the following:

Note: You can also read how to fix Hayward pool heater error codes problem.

Common Pool Heater Error Codes Explained + How To Fix

This article may contain links from our partners. Please read our Disclaimer for more information.

Download our free Pool Maintenance Starter Kit and learn how to manage your pool affordably and efficiently.

Download our free Pool Maintenance Starter Kit and learn how to manage your pool affordably and efficiently.

A pool heater makes swimming possible in the cooler months of the year. So you can use one to start swimming sooner or extend it. But heres the kicker! Like all machines, pool heaters can fail or malfunction, and during that time, using the pool can be daunting.

If you run a commercial pool, this will translate to lost revenue. And if you have a domestic swimming pool, it would mean no fun for you, which can be devastating.

The best way to solve pool heater errors is to know where the problem is coming from. The good news is, you dont have to stress over it when you have pool heater error codes.

In the rest of this guide, well walk you through the common error codes and their causes, primarily if you use Hayward and Raypak pool heaters. So, lets get to it!

  • The Bottom Line
  • You May Like: How To Patch Pool Deck

    Other Common Hayward Pool Heater Codes

    There are at least 14 error codes in most Hayward pool heater models. We will explore the most frequent errors that users suffer within this section. However, if you need to take a detailed look at all the error codes and how to solve them simply, read our article on Hayward pool heater error codes.

    What Causes The Bo Code On A Hayward Heater

    Success: Hayward H400IDL2 gas heater electric start IF Code : pools

    A BO code on your pool heater indicates a bypass operation. When you are using a remote thermostat to control temperature, a BO code will normally display on your heater, and this is normal. However, a BO can also be triggered if the dip switch is flipped to the on position even if you are not using an external controller.

    Don’t Miss: How To Test Pool Chemicals

    What Is Causing My Pool Heater To Malfunction

    A low gas pressure, insufficient air supply, or poor venting might all be contributing factors. Check to see that the gas is switched on, and that the propane tank is filled with fuel. Ensure that there isnt any water coming in from the roof or sprinklers that is flooding the heater. Check to see that the heater pilot tubing is not blocked and that it is in good working order.

    Hayward Pool Heater Error Code Bo

    The error code, bO stands for bypass operations. Our experts do not recommend any bypass terminal for Hayward Pool heaters. However, this code can flash if you are using a remote thermostat. Not to worry, you wont require any troubleshooting in such cases. But, in a manual thermostat, you will have to set the settings accordingly.

    Also Check: Is The Pool Frog Worth It

    Hayward Pool Heater Service Light If

    The IF error code in the Hayward pool refers to ignition failure. Here are the usual reasons that cause this error:

    • The gas shutoff outside the heater is closed.
    • The gas valve inside the heater is turned off.
    • Issues with the wiring of Flame sensor and gas valve.
    • Incorrect gas static, manifold, and load pressures.
    • Faulty gas valve.
    • Damaged blower air inlet plate.
    • Blockage in gas orifices and burners.

    Hayward Pool Heater 5f Code

    Hayward H400FD pool heater fixed igniter issue no thanks to Hayward support

    Hayward Pool heater 5F code or SF code mainly indicates the sensor failure of the heater. Temperature sensor or thermistor failure is specified here for the error indication code of SF. The root reason behind this error includes faulty sensor wiring connection with the board, dirty sensor, or a bad control board. Sometimes, the defective temperature sensor is the only culprit.

    Anyway, when the error persists, you will surely have to replace the temperature sensor. But before replacing it, you need to find out which reasons are actually causing it and how to replace this issue effectively. Read through our comprehensive discussion to learn in detail.

    You May Like: What Shock To Use In Saltwater Pool

    What Happens If Your Heat Exchanger Is Cracked

    If youre lucky, your furnace will stop working, but most of the time, it will continue to operate with a crack, enabling carbon monoxide to flow into your home. No heat in the winter, recurring flu-like symptoms, or a blaring carbon monoxide alarm is the only signals of a malfunctioning heat exchanger.

    How To Put Hayward Heater In Bo Mode

    Heres how you get your heater in Bypass Operation mode. You need to put the heater in STANDBY Mode to get the bO code on the heater display. Press the mode button once to get the heater in STANDBY Mode.

    First, press and hold on to the Down key. Then, press and hold down the MODE key as well. You need to keep holding both the keys for about three seconds. At this point, the bO message should appear on the display.

    Recommended Reading: How Much Does An Above Ground Pool Pump Cost

    Hayward Pool Heater Lo Code Troubleshoot And Diagnosis

    You should only hire a professional to do Hayward pool heater troubleshooting if you have no idea how to or dont have the time to do it yourself. Hiring an expert is always the best way to keep your pool heater in top condition and avoid any major problems from happening.

    The LO code can be caused by a variety of different factors, including:

    Defective Water Pressure Switch: Operate the water pump, making sure there is enough flow and that all connections are secure. Clean any filters that may be present, and replace the water temperature switch if necessary.

    Defective Temperature Limit Switch: Make sure there is enough flow and the connection is good. If necessary, replace the temperature limit switch.

    Defective Vent Pressure Switch: Make sure there is enough flow and that everything is properly connected. If necessary, replace the vent pressure switch.

    If you want to clear the LO code on your Hayward heater, youll need to take care of any issues with the limit switches and wiring. In addition, make sure the water pressure is set correctly for your installation .

    Hayward Pool Heater Service Light Ce

    Hayward HP21254T 125000 BTU Square Pool Heater

    The CE error code stands for Communication Error. Its displayed when the communication between the control module and the display board doesnt work properly.

    This problem can be caused if there is an issue with the ribbon cable that attaches to the display interface. Inspect the cable and check if its secure and that there are no burned or corroded areas.

    Read Also: What Can I Use To Clean My Vinyl Pool Liner

    Hayward Pool Heater Service Light Bd

    This code is a cause of worry as it signals a bad board. Here are the common reasons behind the BD error code:

    • A blown-out fuse board.

    Here are the potential solutions to fix the BD error code:

    • Remove the FC4 fuse to measure continuity.
    • Pull the connector from P6 of the fuse board and make sure the voltage is 110-125 VAC across Pins 3 and 5.
    • Take off the P4 connector from the fuse board and check for voltage between 110 -125 VAC in pins 4 and 6.
    • Replace the fuse board if the voltage between 110 -125 VAC is present.
    • If the voltage is not present, the transformer needs to be replaced.
    • Disconnect the plug from the E10 connector of the control board and check for 110 -125 VAC in pins 1 and 3 of the wire harness.
    • If the voltage is present, the control board needs to be replaced.
    • If the voltage is not present, the wire harness must be replaced.

    Faulty Temperature Limit Switch

    Another reason why your Hayward heater may display the LO code is due to a defective temperature limit switch. As the name suggests, the temperature limit switch has the role of limiting the temperature of the pool heater to within safe limits. Its also called the furnace plenum thermostat. If its faulty, the LO code might be displayed.

    Diagnose a faulty temperature limit switch as follows:

  • Check for the wiring to ensure its not faulty.
  • Check the state of the contacts of the temperature limit switch.
  • Check for the adequacy of the water flow.
  • Check if the temperature limit switch is working correctly or is defective.
  • Other Hayward heater codes may appear if some of these parts arent working correctly.

    Fixes

    For the above issues, the fixes are as follows:

  • Securely fasten the wire harness terminals to the spade terminals of the temperature limit switch. Also, correct any other wiring and connection issues on the pool heater.
  • To verify the contacts to the temperature limit switch, remove the wire leads both from the jumper leads and the limit switch then operate the heater as you measure the continuity across the limit switches. If its open, the LO code is caused by a fault in the temperature limit switch. If closed, try the next step. After that, remove the jumper then reconnect the leads to the temperature limit switch.
  • Adequate water flow should be 20 GPM , 25 GPM , and 30 GPM . Any values lower than that will lead to the LO code.
  • You May Like: How To Test Cya In Pool

    How Do You Fix The Ignition Failure On A Hayward Pool Heater

    Heater switchTake a jump start cable and make contact between the metal terminals on the power switch. This will bypass the ignition switch and jump-start the heater if it’s functional. If the heater comes on, then the heater switch is the cause of the ignition failure and would need changing.Feb 22, 2021

    Why Is My Pool Heater Creating Pounding Sounds While All Of This Is Considered

    Hayward Gas Heater “CE” Code

    To put it simply, the popping noise is caused by water boiling under the sediment. As you can see, sediment settles at the bottom of the tank, where the gas burner is located . However, although the noise itself is innocuous, a buildup of sediment may lead to the following consequences: Eventually causing a leakSediment hinders heat transmission from the gas burner to the water.

    Read Also: How To Make Your Pool Water Clear