Hot Tub Breaker Keeps Tripping

- Advertisment -

What Customers Are Saying:

Does your hot tub keep tripping the breaker? WATCH THIS!

You did one super job of explaining to me everything there is to know about this fridge. I’m looking forward to asking you questions in the future.

JimmyBagley, IA

Wonderful service, prompt, efficient, and accurate. Couldn’t have asked for more. I cannot thank you enough for your help.

Mary C.Freshfield, Liverpool, UK

This expert is wonderful. They truly know what they are talking about, and they actually care about you. They really helped put my nerves at ease. Thank you so much!!!!

AlexLos Angeles, CA

Thank you for all your help. It is nice to know that this service is here for people like myself, who need answers fast and are not sure who to consult.

GPHesperia, CA

I couldn’t be more satisfied! This is the site I will always come to when I need a second opinion.

JustinKernersville, NC

Just let me say that this encounter has been entirely professional and most helpful. I liked that I could ask additional questions and get answered in a very short turn around.

EstherWoodstock, NY

Thank you so much for taking your time and knowledge to support my concerns. Not only did you answer my questions, you even took it a step further with replying with more pertinent information I needed to know.

RobinElkton, Maryland

Check For Corrosion Or Damage In The Heater

Is your hot tubs heater in good shape? If not, it can also result in circuit breaker tripping. The area around your spa is obviously a moist environment, which means some of the components in your hot tub could be subject to rust or corrosion over time.

Inspect the heater and check if there could be rust, white powder, or any other tell-tale signs of corrosion. If you dont find any, you can still double-check if the heater is the culprit. Just disconnect it from the control box and switch on the breaker. If it stays on, you can confirm that the heater was the problem, and your best bet would be to change it out.

How To Fix A Tripped Hot Tub Gfci Circuit Breaker

Finally, youre the owner of the hot tub youve always wanted. Ever since you first brought it home, its provided you with nothing but peace, relaxation, and comfort. Except for one small thing: The GFCI circuit breaker keeps tripping, shutting off the power to your spa just when youre settling in for a soak.

GFCI issues are a relatively common occurrence with hot tubs, and often can be resolved with little fuss or expense. However, because electricity and water are an extremely dangerous combination, make sure you know what youre doing before troubleshooting any electrical problems. Unless youre confident in your ability to address GFCI issues yourself, always consult a professional hot tub repair expert or electrician. An improperly-wired hot tub can result in electrocution or an electrical fire. Electrical work such as installing a hot tub or making adjustments to its components or wiring must be performed by a licensed electrician and must adhere to all local and national electrical codes. As a reminder, always turn off your hot tub and disconnect it from the power supply before attempting any repairs.

Recommended Reading: Can I Use Water Softener Salt In My Pool

Why Does My Gfci Trip At Random Times

Your GFCI may trip at seemingly random intervals, either while youre in the middle of a soak or when your hot tub is not in use. If your GFCI constantly trips, one of the following issues might be the culprit:

  • Your hot tub heater may be corroded or otherwise damaged. Problems with the heating elements are among the most common causes of GFCI issues. Inspect your heater for visible signs of damage, and try operating your hot tub with the heater disconnected to see if the GFCI problem reoccurs.
  • Your spas electrical contacts have become corroded. Inspect each contact and replace any that show signs of corrosion.
  • One or more electrical connections is loose. With the power to your spa disconnected, tug gently on each connection, then tighten and secure any that seem to be loose.
  • The control box containing your GFCI has been exposed to moisture, such as rainwater or condensation. If the inside of your control box is damp, locate the source of the moisture, protect your box from future water exposure, and allow it to thoroughly dry out before testing the GFCI. If water has damaged any electrical components, replace them.
  • Theres a short in one or more of your electric components. Run your spa for 15 minutes, then turn it off, unplug your tub, and inspect your components by hand. Electrical components that are shorting out will feel warm to the touch. Replace any components which grew warm during your test.

Make Sure Your Gfci Breaker Is In Good Condition

10 Common Causes for a Hot Tub Breaker to Trip

Ground fault circuit interrupter breakers are designed to withstand continued use, but they still age and wear out over time. If your breaker has gone through wear and tear and is no longer in good condition, tripping might be expected.

You can try a simple test to find out if you have a bad breaker. First, switch on the hot tub circuit breaker. If it immediately trips again, disconnect everything else from that breaker. Then, flip the GFCI breaker back on. If it doesnt trip, another component might be the problem. If it does trip again, the breaker itself is the issue, and you might need to get a new one.

Recommended Reading: Where Is Doheny Pool Supply Located

Reasons Your Hot Tub Circuit Breaker Keeps Tripping

Having a hot tub at your Phoenix home should provide you with a great way to relax. When your hot tub circuit breaker keeps tripping, though, you might end up feeling more stressed overall. What are some reasons that this might be happening? Having a circuit breaker trip on a frequent basis can indicate a serious issue. These are some of the more common ones that might cause you to suddenly lose power to your hot tub.

Rule Out Whether Its Caused By An Overload Or Loose Connections

While chances of an overload are slim, its still worth ruling out, especially if you recently added a new appliance to the circuit feeding the hot tub. You may have overlooked that the power deficit caused by the additional gadget goes over the intended limit of the breaker, causing it to trip.

If the hot tub trips the breaker when jets are turned on, know that some jacuzzis have jet pumps with high amp draws. If you run them all at the same time along with the heater, it may go over the limit, too.

Secondly, confirm whether its being caused by loose connections. Im more confident of this one as being the probable reason than an overload.

Im referring mostly to the electrical connections of the jacuzzi they may detach over time, causing spikes in the power draw and leading to trips. It may even have been accidentally gotten loose by the previous user, you never know.

Thirdly, check for signs of water leaking onto the motor or the breaker box. Any trace of moisture on the tubs engine or the breaker box that is serving it can cause it to trip frequently. Most GFCI breakers, assuming its the one youre using in your setup, are sensitive to the presence of moisture.

These three problems solutions are pretty simple.

Recommended Reading: How To Drain Water From Pool

Loose Or Damaged Wiring

While youre looking for signs of corrosion, look for other signs of damage to component wiring, such as breaks or char marks. Also check all connections to ensure theyre snug.

Wiring Short: When two wires touch but theyre not supposed to, a surge of power causes your breaker to trip. This can also happen when a hot wire touches a ground wire. Not only will it trip your hot tub breaker, but it can even start a fire. Wires can accidentally touch each other in this manner if youve moved your spa, done work inside the cabinet, or if you have a pest.You can narrow down the offending wires by disconnecting each spa component one at a time. Flip the breaker and see if it trips. When it trips, youve found the misbehaving component. Start inspecting the wiring for that component.If the wires are touching because one came loose, you can reconnect it and reset your hot tub breaker. Signs of damage or signs of a mouse nest mean you should be looking closely for more extensive problems, such as chewed wires. In those instances you might need to replace wires and connectors.

Gfci Breaker For A Hot Tub Keeps Tripping Right Away

7 Reasons Your HOT TUB Breaker is TRIPPING | Swim University
Tags

UL 943 now requires a permanently connected ground-fault circuit interrupter to be provided with an auto-monitoring circuit that will periodically and automatically test the ability of the GFCI. UL 943 also contains new requirements for power denial to the GFCI receptacles and any downstream connected devices when the GFCI reaches its end of life.“Hanging ceiling fans for grandma”M E T G A !

Also Check: Which Is Better Fiberglass Or Concrete Pool

My Hot Tub Is Intermittently Tripping The Breaker It Goes

My name is Garry. I’ll be glad to assist you with your spa.

Most spas have a 50 amp double pole circuit breaker with GFCI protection. The easiest way to tell if your breaker is GFCI protected is that the breaker will have a little test button mounted to the front of the breaker.

GFCI stands for Ground Fault Circuit Interrupt. This is there to protect the spa users from electrical ground faults which could cause a problem if it becomes present in any of the electrical equipment connected to the Control Box being used in your spa.

The reason I’m explaining what a GFCI breaker does is to go a step further based on the diagnoses of your “hot tub tech”.

If the two speed pump motor is running for more than two hours, heating up, then tripping the breaker, this could mean that over time the motor is allowing electrical current to pass to ground, causing the fault, which the breaker will sense and then shutting down. Once the motor sits for a while and cools down, the fault will clear until it heats up and then does it again.

I am assuming you do have this type of GFCI breaker. However, if you just have a regular non-gfci breaker, it could also be possible that the pump motor is overloading after running for more than two hours, and tripping because of high current draw.

If the pump is tripping for any of the mentioned reasons, the only fix for it is to replace the pump/motor.

Does my explanation sound reasonable?

Where Can I Find Replacement Components Or Gfcis

Your local hardware store will likely have replacement GFCIs and components for sale, or you can order them online. If youre not certain which model or configuration to purchase, talk to a repair professional or licensed electrician. The best way to find components for your hot tub is often by visiting the dealer who sold it to you. They will have advanced knowledge of your specific model and will either have parts in stock, or will be able to order them for you. Theyll also have experience diagnosing and repairing similar problems and may be able to offer repair services or advice.

A GFCI circuit breaker that trips constantly is at best a nuisance, and could be an indication of a potentially hazardous situation with your hot tub. Armed with a little knowledge, you should be able to diagnose the problem with your GFCI and find a way to fix it, either by repairing it yourself or by calling upon the knowledge and services of your hot tub dealer or a licensed electrician. A tripped GFCI can be frustrating, but it doesnt have to get in the way of your enjoyment of your hot tub.

Don’t Miss: How To Convert Your Above Ground Pool To Saltwater

Pool Pump Breaker Wont Reset Heres What To Do

If the breaker wont reset for your pool pump, its time to test it. The AstroAI Digital Multimeter is my go-to for testing circuit breakers.

Prices pulled from the Amazon Product Advertising API on:

Product prices and availability are accurate as of the date/time indicated and are subject to change. Any price and availability information displayed on at the time of purchase will apply to the purchase of this product.

Place the red and black nodes on the two wire ports to find out if its getting the proper voltage.

If the pump isnt showing 110v or 220v, the circuit breaker needs to be replaced.

Other issues include the following:

  • The pump is overheating, which prevents the circuit breaker from resetting.
  • Your pumps GFCI needs to be reset before the connected breaker can reset.
  • Theres an electrical outage in your area.
  • The pool equipment pads total amps are more than the circuit breaker can maintain.
  • The bus bar disconnected from the breaker, which prevented it from supplying any electricity.

Pool pump breakers can usually be reset, but that doesnt mean theyre without fault. A malfunctioning or overloaded breaker can turn on and off randomly.

Below, Ill cover several potential reasons your breaker keeps tripping when the pool pump is on.

Broken Gfci Breaker Or Outlet

Hot Tub Breaker Tripping

If youve been using the breaker for years now, you may want to consider its age as a factor for regular breaker trips. If the hot tub breaker trips randomly, thats usually a trickier problem to solve since we also need to look at the faulty component angle. However, it could be due to this one since its also a number-one sign of a breaker thats about to go belly up.

My advice for this is the same for any kind of circuit breaker that has died: replace it as soon as possible. Whether youll do it yourself or have an electrician do it for you is entirely your call.

Recommended Reading: How To Keep Dog Out Of Pool

Hot Tub Gfi Keeps Tripping

Welcome to Flickr!SSjones1088SstickshiftJustin SmithSSjones10886Gunguy45SSjones1088Justin SmithGunguy45SSjones1088Sstickshift12ray2047SSjones1088Sstickshift16ray2047he said he can come out and take a look at it but he has no idea of what it could beSSjones1088Sjones1088The electrician told me to get that kind of wire, its nice to know that i spend $160 on wire, and now i need to replace it!! But would that be causing the gfci to trip?SSjones1088Sjones1088The breaker on the inside panel is also a 50 amp breaker. The hot tub is outside, right up against the basement wall. The wire goes through he basement wall, directly into the back of the disconnectwhich is about 5 feet from the hot tub. From there, the wire is in conduit going directly into the hot tub.I then wired the hot tub directly to the main panel, skipping the gfi, and it runs perfectly fine.21ray2047SSjones1088IibpooksSjones1088Yeah the electrician said he hadnt seen any like that either, he said the two hots usually arent that close to eachother and they usually arent that close to the neutral bar. I bout that at home depot, it came as a kit with the 50 amp gfi breaker inside, it said it was for hot tubs…SSjones1088Ffrench277V27CasualJoeFfrench277V

Moisture In Your Hot Tub Breaker Box

Pop open the breaker box, shine the flashlight around in there, and see if you find any moisture inside. Rainwater, splashout, or flooding can introduce enough dampness to flip a hot tub GFCI.

The solution may be as easy as drying the inside of the breaker box with your towel, turning a fan or dehumidifier on near your outlet, and resetting the breaker once dry.

If the breaker flips even after it appears dry, you may need more extensive troubleshooting. If the breaker is encountering moisture often, you may need to replace the receptacle itself or move it farther from the spa.

Don’t Miss: Does Walmart Have Pool Sand

Check For Moisture In The Breaker Box

A little bit of moisture in your circuit breakers control box is enough to turn off its switch. This is actually an incredibly important function to protect the breaker and the hot tub from the damage that water can cause.

All you need to do is conduct a thorough sweep in the breaker box to find out if moisture is present. Remember to turn off the main electrical supply before you do your inspection. If you find any moisture, use a towel or any absorbent cloth. To make sure its really dry, you can run a fan or dehumidifier near the outlet as well. Then you can proceed to reset the breaker.

Its a good idea to keep your breaker from getting wet in the first place to avoid having to deal with this issue again. To prevent moisture from getting into the panel, make sure that the cables are sealed tight and the rubber seal is intact. If everythings dry and the breaker still flips, it might be necessary to replace the receptacle.

What Is A Gfci Circuit Breaker

Hot Tub GFCI Breaker Keeps Tripping?

A GFCIa Ground Fault Circuit Interrupteris a device used to protect your hot tub from unusual fluctuations or deviations in your power supply. Ground faults and short circuits occur when electricity takes a path the designers of the circuit didnt intend. When a GFCI detects an anomaly in the electrical supply, such as a ground fault or a short circuit, it interrupts the circuit and cuts off all electricity to your spa. When this interruption occurs, its often referred to as tripping the GFCI.

Recommended Reading: What Is The Best Above Ground Pool Light